Terms
- For the greatest combination of pressure and compression ratios the double acting-two stage - double air head models are ideal.
- There are six double air head - two stage boosters, DLE5-30-2, DLE15-30-2, DLE15-75-2, DLE30-75-2, DLE30-75-2-25 and DLE30-75-2-30.
- These boosters provide maximum flow in low air drive and gas supply pressure conditions.
Item # |
Compression Ratio |
Minimum Supply Pressure (Basic Operation) |
Minimum Supply Pressure (Maximum Outlet) |
Maximum Supply Pressure |
Maximum Outlet Pressure |
List Price |
Add To Cart/Request Quote |
---|---|---|---|---|---|---|---|
DLE5-30-2 | N/A 90:1 | N/A 30 psi | N/A 100 psi | N/A 1.0 x Pa | N/A 8,700 psi | QUOTE | Request Quote |
DLE15-30-2 | N/A 40:1 | N/A 100 psi | N/A 220 psi | N/A 15 x Pa | N/A 8,700 psi | QUOTE | Request Quote |
DLE15-75-2 | N/A 100:1 | N/A 100 psi | N/A 220 psi | N/A 5.0 x Pa | N/A 21,750 psi | QUOTE | Request Quote |
DLE30-75-2 | N/A 50:1 | N/A 220 psi | N/A 450 psi | N/A 24.0 x Pa | N/A 21,750 psi | QUOTE | Request Quote |
DLE30-75-2-25 | N/A 50:1 | N/A 220 psi | N/A 1,300 psi | N/A 40 x Pa | N/A 25,000 psi | QUOTE | Request Quote |
DLE30-75-2-30 | N/A 50:1 | N/A 220 psi | N/A 3,300 psi | N/A 40 x Pa | N/A 30,000 psi | QUOTE | Request Quote |