At Maxpro Technologies, we carry a full line of quality Maximator Air Actuated Valves for Hydrogen Service. These valves are a great option for slow fill processes in compact filling stations up to high flow rates for hydrogen fueling stations for buses, trucks, and trains.
Unit of Measure
Ordering Information
|
Technical Data
|
Materials
|
Dimensions
|
Specifications
|
Additional Description
|
Note
Ordering Information
Valve Series Operating Pressure |
N/A 15,200 psi1,050 bar |
Outside Diameter (OD) Tube Size |
N/A 1/4 in |
Body Pattern |
N/A Two-Way Straight |
Configuration |
N/A Compact Air-Drive Normally Open |
Technical Data
Operating Temperature |
N/A 185 ºF-40 ºF |
Air Drive Pressure |
N/A 58 to 116 psi4 to 8 bar |
Materials
Valve Body Material |
N/A 1.4404 (Stainless Steel (SST 316L)) |
Valve Stem Material |
N/A 1.4980 (Alloy (A-286)) |
Seal Material |
N/A Ultra High Molecular Weight Polyethylene (UHMWPE) |
Dimensions
Normally Closed Height |
N/A 6.04 in154 mm |
Normally Open Height |
N/A 3.917 in99.5 mm |
Diameter |
N/A 3.54 in90 mm |
Orifice Size |
N/A 0.78 in2.0 mm |
Specifications
Port Size |
N/A 1/4 MP |
Actuator |
N/A 3MNO |
Actuator Type |
N/A Compact Normally Open |
Stem Type |
N/A Vee Stem |
Media |
N/A Air Hydrogen |
Mark1 | N/A Explosion Proof (EX) |
- 1 The valves are marked with an EX sign and are in conformity to Group II Category 2G Explosion group IIC constructive safety.