  • MAXPRO® offers five gas boosters in the single acting - single stage configuration.
  • These booster models include the DLE2-1, DLE5-1, DLE15-1, DLE30-1 and DLE75-1.
  • Single stage - single acting boosters are the smallest and lightest of the Maximator® family, yet capable of output pressures up to 10,000 psi.
Unit of Measure

Pressure Ratio

N/A 75:1

Compression Ratio

N/A 20:1

Minimum Supply Pressure (Basic Operation)

N/A 500 psi

Minimum Supply Pressure (Maximum Outlet)

N/A 550 psi

Maximum Supply Pressure

N/A 10,875 psi

Maximum Outlet Pressure

N/A 10,875 psi

Stall Pressure

N/A 75 Pa

Inlet Gas Connection

N/A 9/16 in.-18

Outlet Connection

N/A 9/16 in.-18

Maximum Frequency

N/A 130 Cycles/min

Displacement Per Cycle

N/A 1.5 in³

Max. Temperature

N/A 210 ºF

Weight

N/A 29 lb

Output Pressure

N/A Up to 10,000 psi

Features

N/A
  • Pressures to 21,750 psi for most gases and 5,000 psi for oxygen
  • Easy to install and operate
  • Compact, lightweight design
  • Single or double acting and two stage models
  • Double air head available in single and two stage boosters
  • No electrical power required
  • Requires no lubrication
  • Boosters are contaminant free
  • Units can be operated in series or parallel
  • Variety of pressure and compression ratios available

Option Available

N/A Air Control Unit (ACP) Air pilot pressure switches Filters Gas receivers High pressure valves, fittings and tubing Miscellaneous plumbing components Pressure gauges

Accessories

N/A All MAXPRO® gas boosters are available with an optional air control unit (ACP). This package is shown below and consists of an air filter, regulator with gauge, shutoff valve and necessary fittings and hose for plumbing unregulated pilot port

MAXPRO® offers a wide variety of other accessories to assist the installation of your Maximator® gas booster.
  • Gas receivers
  • Pressure gauges
  • Air pilot pressure switches
  • Filters
  • High pressure valves, fittings and tubing
  • Miscellaneous plumbing components

Note

N/A * = Minimum required for basic operation
** = Minimum required to achieve maximum outlet pressures
Pa = Drive air pressure, 145 psi maximum, 15 psi minimum
Ps = Gas supply (suction) pressure
The 9/16-18 is a 1/4" O.D. tubing, high pressure coned and threaded connection.
Stall pressure must not be allowed to exceed outlet pressure rating.
Compression ratio is the minimum required ratio of outlet pressure/supply pressure.
Adapter 15A4H4P is available to convert the 9/16"-18 connection to 1/4" FNPT. Order separately.