|
|
|
L150-VE, L Series Liquid Pump
|
List Price QUOTE
|
|
|
Pressures from 165 to 101,000 PSI
L pumps are available as single acting with either a single or double air drive head and double acting with single air drive head.
|
|
|
|
|
|
|
|
|
Pump Type
|
|
Single Air Drive Head
|
|
Pressure Ratio
|
|
1:151
|
|
Maximum Outlet Pressure
|
|
21,025 psi
|
|
Displacement Per Cycle
|
|
0.40 inĀ³
|
|
Inlet Connection
|
|
1/2 in
|
|
Outlet Connection
|
|
9/16 in.-18
|
|
Weight
|
|
30 lb
|
|
Dimension A
|
|
12.13 in
|
|
Dimension AS
|
|
10.19 in
|
|
Dimension B
|
|
8.38 in
|
|
Dimension C
|
|
3.44 in
|
|
Dimension D
|
|
6.88 in
|
|
Dimension E
|
|
7.81 in
|
|
Dimension F
|
|
3.81 in
|
|
Air Drive Pressure
|
|
15 to 145 psi
|
|
Body Material
|
|
Stainless Steel
|
|
Inlet Liquid Connection
|
|
1/2 in
|
|
Outlet Liquid Connection
|
|
9/16 in.-18
|
|
Air Drive Pressure
|
|
15 to 145 psi
|
|
Air Inlet
|
|
1/2 in. Female National Pipe Thread (FNPT)
|
|
Features
|
|
- Easy to install and operate
- Pressure maintained without energy consumption
- Explosion proof, no electrical power required
- Pilot air control for remote operation standard on many models
- External spool valve for quick maintenance on most models
- Dry air spool valve option available for severe service applications
- Chemical service pumps are standard with separation fitting
- Optional seal materials, port connections, double acting, multiple air heads, single stroke, adjustable stroke, special pumps, just ask
- L series pumps have stainless steel bodies and 17-4 plungers.
- All L pumps have UHMWPE (Ultra-High Molecular Weight Polyethylene) seals and Fluorocarbon (FKM)2 O-rings (-VE), except as noted.
- L series pumps come standard with a bottom or side inlet. For side inlet, add - S to catalog number.
- Air drive pressure range is 15 -145 psi unless limited by outlet pressure.
- Air drive inlet is 1/2" FNPT.
- For air control option, add-ACP to catalog number.
- All L pumps come with an unregulated pilot port, 1/8" FNPT, in the top cap. This feature provides more accurate pressure control and is an ideal location for control instrumentation.
- All L pumps are available with a double air drive head. This doubles the pressure ratio of the pump, allowing the use of a lower ratio base pump, to provide higher flow rates. It is also used to achieve a given outlet pressure with less air drive pressure Add - 2 to the catalog number.
|
|
|
|
|
|
|
|
|
|
|
|
|