Home > High Pressure Air Driven Liquid Pumps > Water or Oil Service > L Series Liquid Pumps >   L150-2-VE  


  L150-2-VE, L Series Liquid Pump

List Price QUOTE

Pressures from 165 to 101,000 PSI

L pumps are available as single acting with either a single or double air drive head and double acting with single air drive head.




 Specifications 

Pump Type

Double Air Drive Head

Pressure Ratio

1:300

Maximum Outlet Pressure

42,050 psi

Displacement Per Cycle

0.40 inĀ³

Inlet Connection

1/2 in

Outlet Connection

9/16 in.-18

Weight

40 lb

Dimension A

15.50 in

Dimension AS

14.00 in

Dimension B

12.25 in

Dimension C

4.00 in

Dimension D

10.81 in

Dimension E

11.81 in

Dimension F

3.81 in

Air Drive Pressure

15 to 145 psi

Body Material

Stainless Steel

Inlet Liquid Connection

View
1/2 in

Outlet Liquid Connection

View
9/16 in.-18

Air Drive Pressure

15 to 145 psi

Air Inlet

1/2 in. Female National Pipe Thread (FNPT)

Features

  • Easy to install and operate
  • Pressure maintained without energy consumption
  • Explosion proof, no electrical power required
  • Pilot air control for remote operation standard on many models
  • External spool valve for quick maintenance on most models
  • Dry air spool valve option available for severe service applications
  • Chemical service pumps are standard with separation fitting
  • Optional seal materials, port connections, double acting, multiple air heads, single stroke, adjustable stroke, special pumps, just ask
  • L series pumps have stainless steel bodies and 17-4 plungers.
  • All L pumps have UHMWPE (Ultra-High Molecular Weight Polyethylene) seals and Fluorocarbon (FKM)2 O-rings (-VE), except as noted.
  • L series pumps come standard with a bottom or side inlet. For side inlet, add - S to catalog number.
  • Air drive pressure range is 15 -145 psi unless limited by outlet pressure.
  • Air drive inlet is 1/2" FNPT.
  • For air control option, add-ACP to catalog number.
  • All L pumps come with an unregulated pilot port, 1/8" FNPT, in the top cap. This feature provides more accurate pressure control and is an ideal location for control instrumentation.
  • All L pumps are available with a double air drive head. This doubles the pressure ratio of the pump, allowing the use of a lower ratio base pump, to provide higher flow rates. It is also used to achieve a given outlet pressure with less air drive pressure Add - 2 to the catalog number.