Double Acting Single Stage Gas Boosters
Gas Boosters
- Double acting - single stage gas boosters provide twice the delivery flows of single acting boosters at a more constant output.
- Double acting - single stage models include DLE2, DLE5, DLE15, DLE30 and DLE75.
Item # |
Compression Ratio |
Minimum Supply Pressure (Basic Operation) |
Minimum Supply Pressure (Maximum Outlet) |
Maximum Supply Pressure |
Maximum Outlet Pressure |
CAD |
Add To Cart/Request Quote |
---|---|---|---|---|---|---|---|
DLE2 DLE2/Asset/DLE2-5-15-30-75.jpg | Compression Ratio N/A 10:1 | Minimum Supply Pressure (Basic Operation) N/A 0 psi | Minimum Supply Pressure (Maximum Outlet) N/A 60 psi | Maximum Supply Pressure N/A 580 psi | Maximum Outlet Pressure N/A 580 psi |
CAD
N/A STEP File for DLE2 |
Request Quote |
DLE5 DLE5/Asset/DLE2-5-15-30-75.jpg | Compression Ratio N/A 15:1 | Minimum Supply Pressure (Basic Operation) N/A 30 psi | Minimum Supply Pressure (Maximum Outlet) N/A 100 psi | Maximum Supply Pressure N/A 1,450 psi | Maximum Outlet Pressure N/A 1,450 psi |
CAD
N/A STEP File for DLE5 |
Request Quote |
DLE15 DLE15/Asset/DLE2-5-15-30-75.jpg | Compression Ratio N/A 20:1 | Minimum Supply Pressure (Basic Operation) N/A 100 psi | Minimum Supply Pressure (Maximum Outlet) N/A 220 psi | Maximum Supply Pressure N/A 4,350 psi | Maximum Outlet Pressure N/A 4,350 psi |
CAD
N/A STEP File for DLE15 |
Request Quote |
DLE30 DLE30/Asset/DLE2-5-15-30-75.jpg | Compression Ratio N/A 20:1 | Minimum Supply Pressure (Basic Operation) N/A 220 psi | Minimum Supply Pressure (Maximum Outlet) N/A 440 psi | Maximum Supply Pressure N/A 8,700 psi | Maximum Outlet Pressure N/A 8,700 psi |
CAD
N/A STEP File for DLE30 |
Request Quote |
DLE75 DLE75/Asset/DLE2-5-15-30-75.jpg | Compression Ratio N/A 20:1 | Minimum Supply Pressure (Basic Operation) N/A 500 psi | Minimum Supply Pressure (Maximum Outlet) N/A 1,100 psi | Maximum Supply Pressure N/A 21,750 psi | Maximum Outlet Pressure N/A 21,750 psi |
CAD
N/A STEP File for DLE75 |
Request Quote |