Home > Hydrogen Products > Hydrogen Air Valves > Item # 15V6M-H2-AS-CC4M-3MNO  


Item # 15V6M-H2-AS-CC4M-3MNO, Hydrogen Air Valves

List Price QUOTE

At Maxpro Technologies, we carry a full line of quality Maximator Air Actuated Valves for Hydrogen Service.  These valves are a great option for slow fill processes in compact filling stations up to high flow rates for hydrogen fueling stations for buses, trucks, and trains.





Ordering Information  · Technical Data  · Materials  · Dimensions  · Specifications  · Characteristics  · Additional Description  · Note

Ordering Information

Valve Series Operating Pressure

15,200 psi
1,050
bar

Outside Diameter (OD) Tube Size

3/8 in

Body Pattern

4-Way

Configuration

Compact Air-Drive Normally Open


Technical Data

Operating Temperature

185 ºF
-40
ºF

Air Drive Pressure

58 to 116 psi
4 to 8
bar


Materials

Valve Body Material

1.4404 (Stainless Steel (SST 316L))

Valve Stem Material

1.4980 (Alloy (A-286))

Seal Material

Ultra High Molecular Weight Polyethylene (UHMWPE)

Needle Valve Seal Material

Ultra High Molecular Weight Polyethylene (UHMWPE)

Check Valve Seal Material

Polyetheretherketone (PEEK)


Dimensions

Height

5.217 in
133
mm

Net Weight

7 lb
2.9
kg

Diameter

3.54 in
90
mm

Orifice Size

0.78 in
2.0
mm


Specifications

Weight

7 lb
2.9
kg

Port Size

3/8 MP

Actuator

3MNO

Actuator Type

Compact
Normally Open

Stem Type

Vee Stem with Adjustable Stroke

Media

Air
Hydrogen

Includes

Adjustable Stroke
Check Valve

Needle Valve

Mark1

Explosion Proof (EX)
1 The valves are marked with an EX sign and are in conformity to Group II Category 2G Explosion group IIC constructive safety.


Characteristics
  • Compact integrated design for high leak integrity
  • Flow through function to dispenser filling hose
  • Double porting on left hand side eliminates need for Tee type fitting
  • Normally open valve for pressure release after filling
  • Bottom port for optional pressure relief valve or rupture disc installation
  • Adjustable orifice to limit noise emissions during pressure release
  • Cone check valve at outlet in order to avoid contamination from vent line
  • Low wear because of optimal choice of materials of construction




Additional Description
Air Actuated H2 Valve Manifolds
  • Pressure release of dispenser filling hoses
  • Adjustable orifice to limit noise emissions
  • Compact design with multiple functions integrated




Note
All technical and dimensional information subject to change. All general Terms and Conditions of sale, including limitations of our liability, apply to all products and services sold.