Print Back
At Maxpro Technologies, we carry a full line of quality Maximator Air Actuated Valves for Hydrogen Service.  These valves are a great option for slow fill processes in compact filling stations up to high flow rates for hydrogen fueling stations for buses, trucks, and trains.
Unit of Measure

Ordering Information

Valve Series Operating Pressure

N/A 15,200 psi1,050 bar

Outside Diameter (OD) Tube Size

N/A 1/4 in

Body Pattern

N/A Two-Way Straight

Configuration

N/A Compact Air-Drive Normally Closed

Technical Data

Operating Temperature

N/A 185 ºF-40 ºF

Air Drive Pressure

N/A 58 to 116 psi4 to 8 bar

Materials

Valve Body Material

N/A 1.4404 (Stainless Steel (SST 316L))

Valve Stem Material

N/A 1.4980 (Alloy (A-286))

Seal Material

N/A Ultra High Molecular Weight Polyethylene (UHMWPE)

Dimensions

Normally Closed Height

N/A 6.04 in154 mm

Normally Open Height

N/A 3.917 in99.5 mm

Diameter

N/A 3.54 in90 mm

Orifice Size

N/A 0.78 in2.0 mm

Specifications

Port Size

N/A 1/4 MP

Actuator

N/A 3MNC

Actuator Type

N/A Compact Normally Closed

Stem Type

N/A Vee Stem

Media

N/A Air Hydrogen
Mark1 N/A Explosion Proof (EX)

Additional Description

Additional Description

N/A Air Actuated H2 Valves
  • Slow fill processes for compact filling stations
  • Hydrogen filling of two-wheelers
  • Pressure release of dispenser filling hoses

Note

Note

N/A All technical and dimensional information subject to change. All general Terms and Conditions of sale, including limitations of our liability, apply to all products and services sold.
  • 1 The valves are marked with an EX sign and are in conformity to Group II Category 2G Explosion group IIC constructive safety.