  DLE30, Double Acting Single Stage Gas Booster

List Price QUOTE

  • Double acting - single stage gas boosters provide twice the delivery flows of single acting boosters at a more constant output.
  • Double acting - single stage models include DLE2, DLE5, DLE15, DLE30 and DLE75.




 Specifications 

Pressure Ratio

30:1

Compression Ratio

20:1

Minimum Supply Pressure (Basic Operation)

220 psi

Minimum Supply Pressure (Maximum Outlet)

440 psi

Maximum Supply Pressure

8,700 psi

Maximum Outlet Pressure

8,700 psi

Stall Pressure

30Pa + Ps

Inlet Gas Connection

1/4 in. National Pipe Thread (NPT)

Outlet Connection

1/4 in. NPT

Maximum Frequency

120 Cycles/min

Displacement Per Cycle

7.3 in³

Max. Temperature

210 ºF

Weight

40 lb

Option Available

Air Control Unit (ACP)
Air pilot pressure switches

Filters

Gas receivers

High pressure valves, fittings and tubing

Miscellaneous plumbing components

Pressure gauges

Features

  • Pressures to 21,750 psi for most gases and 5,000 psi for oxygen
  • Easy to install and operate
  • Compact, lightweight design
  • Single or double acting and two stage models
  • Double air head available in single and two stage boosters
  • No electrical power required
  • Requires no lubrication
  • Boosters are contaminant free
  • Units can be operated in series or parallel
  • Variety of pressure and compression ratios available