Double Acting Oxygen Booster Package - for Higher Flow Rates
Double Acting Oxygen Booster Package - for Higher Flow Rates, Gas Booster Cleaned for Oxygen Service
List Price QUOTE
Download PDF
Download PDF
Printable Page
Email This Page
Save To Favorites
Please wait…
Oxygen Gas Booster Systems
Small, lightweight and economical, MAXPRO® oxygen gas booster packages are ideal for aircraft and bottle filling applications. Requires only an air source for power (70 psi minimum) and an oxygen supply bottle that can be used to as low as 100 psi. These booster packages will achieve up to 2,000 psi outlet pressure. Single (DLE30-1) and double acting (DLE30) boosters are available to meet low flow or high flow requirements.
All stainless steel components, cleaned for oxygen service
Contaminant free operation with complete separation and isolation between the oxygen and air drive sections
No electrical power required, only a 70 psi shop air source
Automatic shut-off at desired outlet pressure for unattended operation
Safety relief devices and pressure gauges included on both gas and air sides
Manual vent valve for venting gas pressure prior to disconnecting outlet line
Drive air filter and shut-off ball valve to manually stop booster
Drive air connection is 1/2" FNPT
Oxygen gas inlet and outlet connections are 1/4" FNPT
All components are mounted to the booster and tested prior to shipment
Compression ratios and the control of heat generated are especially important on pure oxygen systems. Consult MAXPRO® for safety considerations.
MTO2-2-DLE30 for higher required flow rates.
This package is 25"LG x 15"WD x 10"HG and weight approximately 54 lbs.
larger image
larger image
Specifications
Dimensions
25 in. LG x 15 in. wd x 10 in. Hg
Length
25.00
in
Width
15.00
in
Height
10.00
in
Weight
54
lb
Outlet Pressure
1,800 to 2,000
psi
Features
All stainless steel components, cleaned for oxygen service
Contaminant free operation with complete separation and isolation between the oxygen and air drive sections
No electrical power required, only a 70 psi shop air source
Automatic shut-off at desired outlet pressure for unattended operation
Safety relief devices and pressure gauges included on both gas and air sides
Manual vent valve for venting gas pressure prior to disconnecting outlet line
Drive air filter and shut-off ball valve to manually stop booster
Drive air connection is 1/2" FNPT
Oxygen gas inlet and outlet connections are 1/4" FNPT
All components are mounted to the booster and tested prior to shipment