Assembly Instructions

1. The High Pressure Anti-Vibration Collet Gland Assembly
can be installed using the same procedure as the standard
coned and threaded connection. (see above steps 1
through 3) The high pressure collet grips the tube when
the connection gland is tightened.

2. When using the Medium Pressure Anti-Vibration Collet
Assembly, the procedure is the same as that of the
standard coned and threaded connection (see above
steps 1 through 3) with the additional step below.

3. Once the Collet Body has been tightened to the
approriate torque value in the table below, the Collet
Gland can be turned 1 - 1/4 turns past hand tight. This will
compress the collet against the tube. After the initial
compression of the collet, any additional retightening
would only require 3/4 of a turn past hand tight.