• Image

    This unit comes completely assembled, ready for operation. 
     
      • Maximum outlet pressure to 1,500 psi
      • Single stage, double acting
      • Oil free, non-lubricated gas pistons
      • Simple design for ease of operation, ease of maintenance
      • Minimum gas inlet pressure 100 psig
      • 91 inch displacement
      • 100% duty rated
      • Cooling jackets available
      • Many control options are available 
      • Cooling10 HP totally enclosed fan cooled motor, 460v 3ø or 220 1ø
      • 24 VDC on/off control without shutting motor down
      • Maximum Hydraulic oil cooling and filtration circuits with easy spin on filter
      • Hydraulic pressure relief valves to prevent over-pressurization
      • Oil level and temperature sensors
      • Oil Unit as pictured above is 36" deep, 44" wide and 50" tall
      • Liquid cooled gas barrels and long stroke length increases the packing life

    Many control options are available

     Connections:

    • Gas Inlet and Gas Outlet ½" NPT

    • Coolant Inlet and Outlet ½" FNPT


  • Image

    MTHI5-10-PLC
    This unit comes completely assembled, ready for operation. 
     
      • Maximum inlet supply and outlet pressure to 5,000 psi
      • Minimum inlet fluid pressure 100 psig
      • Single stage, double acting
      • Oil free, non-lubricated pistons
      • Hydraulic to process pressure ratio: 1:2
      • Simple design for ease of operation, ease of maintenance
      • Displacement volume per double stroke 33.18 inch3
      • Typical maximum flow 2 gpm process volume
      • Maximum cycles (double stoke) of 15 per minute
      • Stroke Length of 8"
      • 100% duty rated
      • Liquid cooling jackets available
      • Control options are available:

        Motor Starter or

        PLC control and performance monitoring


        The intensifier is purchased as a complete unit
        mounted on the hydraulic power pack.
        The hydraulic unit comes with the following features:
      • 10 HP totally enclosed fan cooled motor, 460v 3ø or 220 1ø
      • 24 VDC on/off control without shutting motor down
      • Maximum Hydraulic oil cooling and filtration circuits with easy spin on filter
      • Hydraulic pressure relief valves to prevent over-pressurization
      • Oil level and temperature sensors
      • Oil Unit as pictured above is 36" deep, 44" wide and 50" tall
      • Liquid cooled gas barrels and long stroke length increases the packing life

     

     Connections:

    • Gas Inlet and Gas Outlet ½" NPT

    • Coolant Inlet and Outlet ½" FNPT

     

  • Image

      • Maximum discharge pressure: 15,000 psi
      • 12.3 compression ratio
      • Minimum operating inlet gas pressure: 1,000 psig
      • Estimated Flow rates: 75 - 165 SCFM depending on gas inlet pressure
      • Ambient operating temperature: 60-90 °F

     


    Single stage, double acting Hydralic Driven Gas Booster
    Features:
    Motor: 40 HP, 480V, 3 phase, 60hz, TEFC
     
    Oil free non-lubricated gas pistons and cylinders
     
    PLC/HMI color touch screen
     
    Safety shut for coolant flow, low hydraulic fluid and hydraulic oil temperature
     
    0-20,000 psig pressure transducer
     
    Solenoid operated coolant flow valve
     
    Option for remote controlled operation
     
    Liquid cooled gas barrels
     
    Fully enclosed
     
    Emergency stop button
    100% duty rated


    The unit is rated for 15,000 psi maximum and will have the following connections:

    • Gas inlet: 9/16" OD medium pressure coned and threaded connection

    • Gas outlet from system: 3/8" OD medium pressure coned and threaded connection

    • Electrical requirements: 480 3 phase

    • Coolant inlet:1/2" FNPT

    • Coolant outlet:1/2" FNPT

© 2017 MaxPro Technologies Inc, All Rights Reserved Site created by Thomas Web Solutions and powered by Navigator Platform